Leading Manufacturers, Exporters, Wholesaler, Retailer of CALsys -1200 Autocal Portable Thermocouple and RTD Calibrator, CALsys -30/110 Autocal Automatic Dry Block Calibrator, CALsys -35/200 Autocal Automatic Liquid Calibration Bath, CALsys 650 Autocal - Portable Thermocouple Calibrator and CALsys-80/50-Autocal Automatic Liquid Calibration Bath from Udaipur.
Business Type | Manufacturer, Exporter, Supplier, Retailer |
Temperature Range | 250 °C to 1200 °C |
Accuracy | ±3°C |
Stability | ±0.1°C at 250°C, ±0.2°C at 700°C, ±0.3°C at 1200°C |
Radial Uniformity | ±0.20°C at 250°C, ±0.24°C at 700°C, ±0.36°C at 1200°C |
Immersion Depth | 160mm |
Insert OD Dimensions | 37mm |
Method of Control | Self Tunned PID Controller |
Heating Time | 60 Min |
Cooling time | 150 min(1200⁰C to 250⁰C ) |
Resolution | 0.1⁰C up to 999⁰C |
Display | Lcd,⁰c or ⁰f User-selectable |
Size (HxWxD) | 405(H) x 205(W) x 285(D) |
Weight | 12 Kg |
Power Requirements | 230 VAC, 1.5 KW(50Hz) |
Computer Interface | Rs- 232 |
Calibration | Accredited Calibration Certificate Provided |
Environmental operating conditions | 0 ⁰C to 40 ⁰C,0 % to 90 % RH(non-condensing) |
Specification valid in environmental conditions | 13 ⁰C ..... 33 ⁰C |
Data logging (CALsys 1200 Autocal) | Data logging facility with logged data export to computer through LAN port (optional USB) |
Preferred Buyer From
Location | Worldwide |
The CALsys 1200 Autocal is an automatic temperature calibration system for the Thermocouple and RTD's.
The system consists of Temperature bath and PC software, which together contribute to the whole cycle of auto-calibration process.
The system accepts 4 channels, 4 Thermocouples or 4 RTD's.The connection for these channels through special type of locking connectors. The channel configuration can be done with LCD display via touch screen keypad.
The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensation. After the calibration process complete the PC software generates a report of actual calibrated values for the inputs.
Key Features:
Accessories:
Input (CALsys 1200 Autocal): Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C (J, K, N, T, R, S, B type) and Rtd.
Software (CALsys 1200 Autocal): The calibrator should be provided with software for data recording (Manual Mode) and Test Certificate generation in Auto Mode.
Business Type | Manufacturer, Exporter, Supplier, Retailer |
Temperature Range | -30 to 110°C |
Stability | ±0.04°C at -30°C, ±0.06°C at 0°C, ±0.07°C at 110°C |
Uniformity | ±0.05°C at -35°C, ±0.07°C at 0°C, ±0.08°C at 110°C |
Standard | CE Certified |
Temperature Resolution | 0.1°C |
Heating Time | 10 min |
Cooling Time | 25 min |
Fixed Insert Dimension | 32 mm |
Depth | 120 mm |
Method of control | Digital Self Tuned PID Controller |
Computer Interface | RS - 232 |
Power Requirement | 230 VAC, 500 W (50Hz) |
Dimensions | 380(H) x 170(W) x 188(D)mm |
Instrument Weight | 11 Kg(approx.) |
Environmental Operating Conditions | 0°C to 40°C, 0% to 90% RH (non-condensing) |
Specifications valid in environmental conditions | 13°C … 25°C |
Preferred Buyer From
Location | Worldwide |
CALsys -30/110 Autocal is a Highly Stable Furnace for calibrating RTD. It offers a temperature range of -30 to 110°C. This calibrator can be used on-site for high-temperature calibration and applications like aerospace, oil gas petrochemical, pharmaceutical industry, electric power, automotive and material process industry. The comparison volume is a metallic fixed block of special material, which has a diameter of 32 mm and 120mm long. Low-temperature dry block furnace based on thermoelectric cooling circuitry.
The CALsys -30/110 Autocal is an automatic temperature of the calibration system for thermocouples and RTDs. The system consists of Temperature bath PC software, which together contributes to the whole cycle of the auto-calibration process. The system accepts 4 channels, 4 thermocouples, 4 RTDs.The channel configuration can be done with an LCD display via a touch screen keypad. The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensation. After the calibration process complete the PC software generates a report of actual calibrated values for inputs.
Key Features:
Accessories
Input: Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C and Rtd.
Software: The calibrator will be provided with software for data recording (Manual Mode) and report generation in Auto Mode.
Data Logging: Data Logging facility with logged data export to the computer through LAN port (Optional USB)
Business Type | Manufacturer, Exporter, Supplier, Retailer |
Temperature Range | -35 to 200°C |
Stability | ±0.01°C at -35°C, ±0.03°C at 0°C, ±0.04°C at 200°C |
Uniformity | ±0.03°C at -35°C, ±0.05°C at 0°C, ±0.07°C at 200°C |
Resolution | 0.01°C |
Cooling Time | 60 min (room temperature to -35°C ) |
Volume | 6 Ltr |
Access Opening | 105 (L) x 105 (W) mm |
Immersion Depth | 150 mm |
Method of control | Digital Self Tuned PID Controller |
Computer Interface | RS - 232 |
Power Requirement | 230 VAC, 2 KW (50 Hz) |
Dimensions | 540(H) x 220(W) x 620(D)mm |
Weight | 65 Kg |
Calibration | Accredited calibration certificate provided |
Environmental operating conditions | 0°C to 40°C, 0% to 90% RH (non-condensing) |
Specifications valid in environmental conditions | 13°C … 25°C |
Preferred Buyer From
Location | Worldwide |
CALsys -35/200 Autocal is a Highly Stable Stirred Liquid Bath for Calibration RTD / Thermocouple and also for compensation of cold junction.
CALsys -35/200 Autocal offers a temperature range of -35 to 200°C. It has a large tank that is filled with liquid (Water+Methanol/Silicon Oil). The liquid is heated or cooled to the desired temperature, where Methanol+Water are used for Negative Temperature and Silicon Oil is for Heating purpose.
It has better stability & uniformity than dry block bath and as it uses of stirred liquid. This CALsys -35/200 is built using CFC-free refrigerants.
The CALsys -35/200 Autocal is an automatic temperature of the calibration system for thermocouples and RTDs. The system consists of Temperature bath PC software, which together contributes to the whole cycle of the auto-calibration process. The system accepts 4 channels, 4 thermocouples, 4 RTDs.The channel configuration can be done with an LCD display via a touch screen keypad. The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensation. After the calibration process is complete the PC software generates a report of actual calibrated values for inputs.
Key Features:
Accessories:
Standard Accessories
Optional Accessories
Input (CaLsys -35/200 Autocal): Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C and Rtd.
Software (CaLsys -35/200 Autocal): The calibrator will be provided with software for data recording (Manual Mode) and report generation in Auto Mode.
Data Logging (CaLsys -35/200 Autocal): Data Logging facility with logged data export to the computer through LAN port (Optional USB)
Business Type | Manufacturer, Exporter, Supplier, Retailer |
Temperature Range | 50⁰C to 650⁰C |
Stability | ±0.01°C at 50°C, ±0.02°C at 350°C, ±0.03°C at 650°C |
Accuracy | ±2°C |
Radial uniformity | ±0.04°C at 50°C, ±0.07°C at 350°C, ±0.09°C at 650°C |
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) | 0.04 °C |
Insert Od Dimensions | 32mm |
Immersion Depth | 120mm |
Cooling Time | 80 Min ( 650 °c to 100 °c) |
Heating Time | 20 Min |
Resolution | 0.1°C |
Display | Lcd,°c or °f User-selectable |
Power requirements | 230 VAC,1KW(SO Hz) |
Calibration | Accredited Calibration Certificate Provided |
Environmental operating conditions | Environmental operating conditions |
Specifications Valid in Environmental Conditions | 13°c … 33°c |
PC Interface | Ethernet port (CALsys 650 PLUS) , RS - 232 (CALsys 650 ) |
Size (H x W x D) | 325(H) x 185(W) x 265(D) mm |
Weight | 10 Kg |
Data Logging(CALsys 650 Autocal) | Data Logging facility with logged data export to the computer through LAN port (Optional USB) |
Preferred Buyer From
Location | Worldwide |
CALsys 650 Autocal offers easy to use portable temperature calibrator with a medium temperature range from 50 to 650°C. It is a highly stable standard furnace for calibrating thermocouples / RTD. This calibrator can be used on-site in workshops, test and measurement rooms as well as laboratories. The comparison volume is a metallic block of special material, which has a diameter of 32mm and 150mm long.
The CALsys 650 Autocal is an automatic temperature calibration system for the Thermocouple and RTD's. The system consists of a Temperature bath and PC software, which together contribute to the whole cycle of the auto-calibration process. The system accepts 4 channels, 4 Thermocouples, or 4 RTDs. The connection for these channels through a special type of locking connector. The channel configuration can be done with LCD display via a touch screen keypad. The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensation. After the calibration process complete the PC software generates a report of actual calibrated values for the inputs. Our newly designed CALsys 650 Autocal model offers better esthetic design and is performance-wise upgraded to the next level. This model offers better cooling time which is 2 times faster than our old model and has stability 30% better than the old CALsys 650 Autocal model. Hence our new model not only saves an important time for our valuable customer but also provides better performance.
With the Tempsens make Compact Temperature Calibrator, you have chosen an extremely effective instrument that we hope will live up to all your expectations. This is a fast, timesaving, and reliable true industrial temperature calibrator designed for on-site use.
Kay Features:
Accessories:
Input(CALsys 650 Autocal): Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C and Rtd.
Software: The calibrator will be provided with software for data recording (Manual Mode) and report generation in Auto Mode.
Business Type | Manufacturer, Exporter, Supplier, Retailer |
Temp Range | -80 to 50°C |
Stability | ±0.04°C at -80°C, ±0.07°C at 0°C, ±0.05°C at 50°C |
Uniformity | ±0.05°C at -80°C, ±0.09°C at 0°C, ±0.07°C at 50°C |
Temperature Resolution | 0.1°C |
Time to Reach Min. Temp | 2 Hrs |
Medium | Methanol |
Controlling Sensor | PT100 |
Volume | 9 Ltr. |
Access Opening | 105 x 105 mm |
Depth | 200 mm |
Method of control | Digital self tuned PID Controller |
Emissivity | 0.95 ±0.01 |
Computer Interface | RS - 232 |
Operating Temperature | 20 to 25°C |
Power Requirement | 230 VAC, 2.0 KW |
Dimensions | 630 (W) x 1200(H) x 500 (D)mm |
Instrument Weight | 100 Kg |
Data Logging | Data Logging facility with logged data export to the computer through LAN port (Optional USB) |
Standard | CE Certified |
Preferred Buyer From
Location | Worldwide |
CALsys -80/50 Autocal is an automatic calibration system for RTD / Thermocouple and also for compensation of cold junction. CALsys -80/50 offers a temperature range of -80 to 50°C. It has large tank which is filled with liquid Methanol. The liquid is heated or cooled to the desired temperature. It has better stability & uniformity than dry block bath and as it uses of stirred liquid.The system consist of a Temperature bath and PC Software, which together contribute to the whole cycle of the auto-calibration process.The system accepts 4 channels, 4 thermocouples or RTDs. The connection for these channels through special type off locking connectors. The channel configuration can be done with LCD display via touch screen keypad. The thermocouple microvolt & RTD ohm reading for each channel is monitored with CJC compensation. After the calibration PC software generates a report of actual calibrated values for the inputs.
Key Features:
Accessories:
Input: Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C and Rtd.
Software: The calibrator will be provided with software for data recording (Manual Mode) and report generation in Auto Mode.